How to Wire Solar Panels in Series-Parallel Configuration?

Series-Parallel Connection of Solar Panels to the Battery and Inverter

For small residential loads, the series-parallel combination of solar panels is less common (but possible) wiring connection to the batteries, AC and DC load through charge controller, battery and UPS/inverter. For different possible wiring systems, we may connect the solar panels and batteries in series, parallel or complex i.e. series-parallel connection according to our needs and designed system.

In this tutorial, we will show the basic wiring of photovoltaic panels in Series-Parallel connection to a single or multiple batteries, charge controller, AC and DC load via charge controller and an inverter.

This arrangement is needed when we want to double the level of voltage (voltage is additive and current is same in series connection) as well as the charging current (current is additive and voltage is same in parallel connection) from solar panel to the batteries and other load points. In this case, we will have to connect multiple solar panels (photovoltaic array) in series parallel connection to the batteries and load points.

By connecting the photovoltaic panels in series-parallel configuration, we get benefits of both connections i.e. doubling the level of voltage and increasing the current rating from solar panels to the batteries and AC/DC load.

Related Posts:

How to Wire Solar Panels in Series-Parallel Connection

Voltage & Current in Series-Parallel Connected Solar Panels

Suppose we have 12V, 10A ,120W solar panels connected in series-parallel connection.

A set of two solar panels connected in series

Series Voltage:

V1 + V2 ….. + Vn

12V + 12V = 24V.     …     (Voltage is additive in series connection)

Series Current:

I1 = I2 ….. = In

10A = 10A = 10Ah     …     (Current is same in series connection).

Now, we have two sets of series connected solar panels. If we connect these two set in parallel:

Parallel Voltage:

V1 = V2 ….. = Vn

24V = 24V = 24V     …     (Voltage is same in parallel connection

Parallel Current:

I1 + I2 ….. + In

10A + 10A = 20A     …     (Current is additive in parallel connection).

Finally, we get 24V, 20A from four PV panels each of 12V and 10A i.e. we doubled both the voltage and current capacity of solar panels e.g. voltage from 12V to 24V and amperage from 10Ah to 200Ah by connecting PV panels in series-parallel configuration.

Related Posts:

Wiring Photovoltaic Panels in Series-Parallel Connection

To do this wiring, make two sets (pairs) of PV panels and connect them in series. This way, you will have two pairs of solar panels connected in series. Now, connect the two sets of series connected solar panels in parallel as shown in the following fig.  Now, you are having four 12V, 10A solar panels connected in series-parallel configuration.

As a next step, you can connect these solar panels to a charge controller. A basic DC load (12 or 24V) can be directly powered up by connecting it to the charge controller.

The AC load can be powered up in two ways. Firstly, it can be directly powered up by solar power during the normal sunshine (day). Secondly, the AC load (120V/230V AC) can be powered up by the stored power in the batteries using an inverter during shading (or night). Keep in mind that the number of solar panels and batteries depends on the load requirements where solar panels keep charging the batteries as well as power up the AC load.

The following solar panel and battery wiring diagram shows how to wire a four 12V Solar Panels in series-parallel connection to a 24V, 400Ah battery with an automatic inverter system. Note that the number of solar panels and batteries depends on the system’s design and load requirements i.e. multiple batteries and solar panels can be connected in series, parallel or series parallel connection to increase the Ah rating and storage capacity. (we have discussed them in previous post).

Wiring PV Panels in Series-Parallel Configuration - 24V

This wiring is fully automatic due to auto UPS wiring i.e. no need to install an auto or manual changeover / ATS switch to change between the solar power or battery storage power to the load points.

Related Posts:

Good to know:

  • Current is additive while voltage is the same in parallel connection.
  • Current is the same while voltage is additive in series connection.
  • Only the same rated solar panel can be connected in series, parallel or series parallel connection.
  • A 12V solar panel can only be connected in (series, parallel or series-parallel) with another 12V solar panel.
  • A 12V solar panel should not be connected (in series, parallel or series parallel) to a 6V or 24V solar panel.

Related Solar Panel Wiring & Installation Diagrams:

Electrical Technology

All about Electrical and Electronic Engineering & Technology. Join us on WhatsApp at Electrical Technology Official Channel, to receive the latest content, articles, and updates. You can also like and follow our social media networks below, or subscribe with your email to receive premium engineering articles in your mailbox.