How to Wire a UK 3-Pin Plug? Wiring a BS1363 Plug

Wiring a BS1363, 3-Pin Plug Safely and Correctly

What is a UK 3-Pin Plug?

A UK plug, also known as a British Plug, Type G Plug, or BS1363 Standard Plug by the International Electrotechnical Commission (IEC), is a three-pin plug used to power electrical appliances and devices. There are multiple types of three-pin plugs, such as Type A, B, C, D, E, F, G, H, I, J, K, L, etc. However, the G type 3-pin plug is most common in the United Kingdom, Singapore, Hong Kong, Malta, Malaysia, Ireland, Cyprus, Qatar, Oman, Kuwait, Saudi Arabia, the UAE, Israel, and other countries that fully or partially follow IEC regulations.

Related Posts:

Inside a 3-Pin Power Plug

There are three terminals and a fuse inside a UK three-pin power plug, as follows:

Click image to enlarge

How to Wire a UK 3-Pin Plug? Wiring a BS1363 Plug
Image Credit: Eugene Brennan – Modified by: Electrical Technology

Live Terminal = L

The live terminal should be connected to the brown-colored wire (from the cable). It carries voltage and current from the source to the load point. The live terminal is also known as the hot, line, or phase terminal. The live terminal screw is electrically connected and bonded to the input of the safety fuse, while the output of the fuse is connected to the live pin.

Neutral Terminal = N

The Neutral terminal should be connected to the blue-colored wire. The Neutral wire provides a return path for the current when the circuit is completed.

Earth Terminal = E

The Earth terminal is longer and thicker for safety purposes. For this reason, the green with yellow stripe Earth wire should be connected to the Earth terminal.

Fuse

There is a built-in standard fuse (normally 13A) in a BS1363 plug. The rating of the ceramic fuse in the UK plug can be different, depending on the current capacity and types of protected loads. The main function of the fuse in a British plug is to protect the power cord, connected appliance, and cables and wires in case of overheating, overload, or overcurrent.

For example, a 13A fuse with 230V, 50Hz home supply voltage is equivalent to almost 3000 watts (3kW). If the load current exceeds the limit of the fuse rating (in the case of a fault, e.g., a short circuit), it will blow or trip the RCD/MCB circuit breaker in the main consumer unit.

Good to Know: The fuse in the three-pin power plug should be rated according to BS1363 standards. For example, if a low-power device (1100W or 700W) has to be used instead of a previous high-power device (2.5-3kW with a 13 Ampere fuse in the power plug), the fuse rating must be reduced according to the load current capacity, e.g., 3A for 700W and 5A for 1100W appliances.

Cable Grip

A cable grip is used to prevent tension on the cable during normal operation and to prevent the wire strands from pulling out of the screw terminals. The strain relief (cable grip) should be tightly fitted around the cable after connecting the wire strands to the appropriate terminals.

Related Posts:

Safety Features of BS1363 Plug

Good to know: The BS-1363 Plug, also known as the UK plug, is considered the safest plug in the world due to the following reasons:

Tools Needed

The following basic tools are required while wiring a 3-pin power plug.

Click image to enlarge

Wiring a Fused Three Pin Plug

Related Posts:

Wiring a UK 3-Pin Plug

Follow these simple steps to wire a BS-1363 UK plug:

  1. Remove 2 inches or 5 centimeters of the outer sheath or insulation of the cable without damaging it, using a knife, snips, or wire stripper.
  2. Shorten the Live and Neutral (Brown & Blue) wires to a length that fits appropriately in the Live and Neutral screw terminals.
  3. Remove about half an inch (10mm) of insulation from the inner cores of all three wires (Brown, Blue, and Green/Yellow Stripe) using snips, a knife, or a wire stripper. Be careful not to damage the wire strands or conductors.
  4. It is a good practice to tightly twist all the wire strands and double them over before inserting them into the screw terminals. This helps avoid spreading the wire strands to other terminals and ensures the screws are tightened properly, especially for light gauge flex.
  5. Loosen the screws on the cable grip (strain relief) to easily connect the phase, neutral, and earth wire to the related screw terminals.
  6. Connect the Green with Yellow Stripe wire to the Earth “E” terminal.
  7. Feed the Blue wire into the Neutral “N” terminal.
  8. Finally, connect the Brown wire to the Live (Phase) “L” terminal.
  9. Tighten the cable grip (strain relief) screws and replace the back cover of the three-pin plug. Ensure all wires and screws are securely tightened to prevent hazardous fires due to arcing, overheating, or electric shock resulting in serious injuries.

Click image to enlarge

Front & Back Side of UK, BS-1363, 3-Pin Plug

Remember:

Related Posts:

IEC & UK Wiring Color Codes: Old & New

We have used the following IEC wiring color codes for 230V single supply voltage applicable in the UK & EU. The older wiring color codes in the United Kingdom (prior April 2004) is also mentioned below.

IEC Wiring Color Codes for 230V, 1-Phase, 3-Wire System

The Old UK wiring color codes for single phase wiring are as follow.

230V Single Phase

Related Posts:

Instruction & Safety Precautions

Related Wiring Installation Tutorials:

↑
Exit mobile version