EE SymbolsMeasuring InstrumentsResistors

Resistor Symbols – Variable, Adjustable & Special Resistors Symbols

Resistor Symbols – Variable & Adjustable Resistors Symbols – Special Resistor Symbols

Resistor Symbols

Resistors Symbols

Resistor (NEMA & IEC Systems)Resistor Symbol - NEMA & IEC

It is the symbol of a fixed resistor. Both of these symbols represent a fixed resistor in NEMA & IEC standards systems.

AttenuatorAttenuator Symbol

An attenuator works opposite to the amplifier. It reduces the power of the signal without distorting it. It dissipates the signal’s power within its own resistor network. The symbol of attenuator is given above.

Preset ResistorPreset Resistor

It is a variable resistor whose resistance is adjusted during manufacturing or designing of the circuit. It is not changed during normal use of the circuit. The resistance of preset resistor is changed using a screwdriver.

Non Reactive ResistorNon Reactive Resistor

These resistors, also known as non-inductive resistors, have pure resistance. A common wire wound resistor has inductance due to the magnetic field produced by the winding. Non-reactive resistors have special winding designs to cancel each other’s magnetic fields.

ImpedanceImpedance Symbol

The impedance is a complex quantity made of real & imaginary part. The real part represent the resistance & the imaginary part represents the reactance.

Heating ElementHeating Element Symbol

This component converts the electrical energy into heat energy. The current flow through the heating element generates heat energy due to its resistance.

Protective ResistorProtective Resistor Symbol

These both symbols represent a protection resistor. It operates like a resistor that limits the current flow & if the current exceeds its certain limit then it blow out opening the circuit.

MemristorMemristor Symbol

Memristor or also known as memory resistor is a hypothetical non-volatile memory component whose resistance depends on the current that has been passed through it in the past. It remembers its last known resistance when it is Powered OFF/ON.

Shunt ResistorShunt resistor Symbol

A shunt resistor (also known as current shunt) is a resistor with low & precise resistance used to measure the current through it. The current is measured by the voltage drop across it. Thus it acts as a current sensor.

Resistor ArrayResistor Array Symbol

Resistor array is a combination of multiple resistors in a single packaging. It contains multiple individual resistors denoted by the number in the symbols e.g 8 in this case.  The resistors are not connected together except for its one side which is connected with VCC for pull up & GND for pull down. They are used for saving space & cost of placing.

Types of Resistors. IEEE & IEC symbols of Resistors
Resistors and Symbols of Different Types of Resistors. IEEE & IEC symbols of Resistors

Variable & Adjustable Resistor Symbols

Variable ResistorVariable resistors symbols - potentiometer and rheostate symbol

A variable resistor also known as potentiometer or rheostate has a variable resistance. It has three terminals. The two of them have fixed resistance while the third terminal move over the resistive trace or wire to increase or decrease the resistance. They are used for increasing or decreasing  the current flow in a circuit during its normal operation.

Continuous Variable ResistorContinuous variable resistor symbol

Such type of variable resistor has a continuous resistance i.e. the sliding or rotating the contact gives out a continuous value of resistance. It can achieve infinite numbers of resistance values ranging from min to max.

Step Variable ResistorStep Variable Resistor symbol

This type of variable resistor’s resistance increase or decreases in steps . The contacts does not slide smoothley but jumps from steps . Each step movement increase or decrease a fixed amount of resistance.

Carbon Pile Variable resistorCarbon pile variable resistor symbol

This type of variable resistor is made up of carbon discs clamped together between two metal plates. Increasing or decreasing the presure between these metal plates increases the resistance of the device.

Variable Resistor with ON/OFF switchVariable resistor with ON-OFF switch symbol

This type of variable resistor has a builting switch that breaks or make the contact between the two termianls.

Preset ResistorPreset Resistor symbols

Preset resistor is a variable resistor that is only operated during menufacturing and tuning a circuit. they are not operated during the normal use of a circuit. there design are not as rigid as a variable resitors (Potentiometer etc).

Variable Resistors Symbols

Special Resistor Symbols

Photo resistor Light Dependent Resistor LDRPhoto resistor Light dependent resistor LDR Symbol

It is a light dependent resistor i.e. its resistance depends on the intensity of the light. The resistance of LDR decreases with increase in the light intensity.

ThermistorThermistor Symbol

Thermistor or thermal resistor is a type of resistor whose resitance depends on its surrounding temperature. It either decrease or increase with the temperature depnding on the type of thermistor.

NTC & PTC ThermistorNTC & PTC Thermistor Symbols - negative temperature coefficient & positive temperature coefficient symbol

NTC stands for negative temperature coefficient & PTC stands for positive temperature coefficient. The NTC Thermistor resistance decrease with increase in the temperature & denoted by –t° sign. The PTC thermistor resistance increase with increase in temperature & denoted by +t° sign.

Varistor VDRVaristor Symbols - voltage dependent resistor VDR Symbol

Varistor or VDR (voltage dependent resistor) is a type of resistor whose resistance depends on the voltage applied. Its resistance varies with the change in the applied voltage. These symbols (some of them are old & new) represent varistor.

Iron Hydrogen ResistorIron Hydrogen Resistor Symbol

It is positive temperature coefficient resistor made of iron wire inside hydrogen filled bulb. Its resistance increase with temperature which is due to the increase in the current flow. The increasing resistance opposes the increase in current. Thus they are used in stabilizing circuit.

Magneto ResistorMagneto resistor Symbol - Magnetic dependent resistor

Magneto resistor or MDR (Magnetic dependent resistor) is a type of resistor whose resistance depends on the external magnetic field. It resistance changes with change in magnetic field intensity & It is a used as a magnetic sensor for sensing magnetic field.

Resistance thermometer or RTDResistance thermometer or RTD Symbol

Resistance temperature detector (RTD) is a temperature sensor whose electrical resistance changes with the temperature. The material used in RTD’s has very accurate relation between the resistance & temperature. It can be measured by supply of constant current & the voltage drop across the resistor.

Special Resistors Symbols

 Related Electrical and Electronic Engineering Symbols:

Electrical Technology

We are a professional team specializing in Electrical and Electronic Engineering & Technology. Join us on the Electrical Technology Official WhatsApp Channel to receive the latest content, articles, and updates. You can also follow us on our social media platforms given below or subscribe via email to get premium engineering articles delivered directly to your inbox.

Leave a Reply

Your email address will not be published. Required fields are marked *

Back to top button