Home » Questions/Answers (Electrical) » Under what condition is D.C supply applied safely to the primary of a transformer?

Under what condition is D.C supply applied safely to the primary of a transformer?

How to Connect a Transformer to DC Supply?

Under what condition is DC supply applied safely to the primary of a transformer?

As i mentioned ,This is a simple electrical interview question. So if some one ask this question in interview or somewhere..then the right answer will be this….I think u got the main Idea
Also
As we know that Transformer works only on A.C, in case of D.C Supply, the primary of transformer may start to smoke and burn….But this is the only one condition where we can operate a Transformer on D.C (although the Circuit is Useless)…For more information….in the above blog…U will see a post where we talked about the topic…..1 Transformer primary with A.C supply, 2. Transformer primary with D.C Supply.

How to Connect a Transformer to DC Supply? Conditions?
Under what condition is DC supply applied safely to the primary of a transformer?
Also Read:

From Schematic Drawing to PCB Production, Just Need One Tool
Cheap PCB Prototype: 10 pcs 2 layers only $10, quick delivery, 100% E-test.

About Electrical Technology

All about Electrical & Electronics Engineering & Technology. Follow , Facebook , Twitter , Instagram , Pinterest & Linkedin to get the latest updates or subscribe Here to get latest Engineering Articles in your mailbox. Also, Follow

Check Also

What is Industrial Automation

What is Industrial Automation | Types of Industrial Automation

What is Industrial Automation, Their Types and Hierarchy of an Industrial Automation System Today’s highly …

5 comments

  1. If we give dc supply to transformer with high series resistance. Then the transformer output will be ac or dc?

  2. Another case is also possible if we supply very low DC voltage I.e almost one tenth of rated value then transformer will not going to burn because than it draw very low current and that current will going to bear by the transformer resistor.

    And as per the answer of question what is the output if we supply DC since due to DC inductor act as short ckt there is no magnetisation of primary and therefore no flux will going to produce by primary so there is linkage of flux with secondary winding so there is no output

  3. sir
    I what when the DC supply is given to transformers some stress in the winding or coil .how much stress in the winding in practical