How to Install a Home and Away Wireless Smart Switch

Wiring Installation of a Home/Away Smart Wireless Switch for Lighting Control

In todays smart devices installation series, we will discuss the adorne® Home/Away Wireless smart switch with Netatmo by Legrand. The installation guide, along with wiring diagrams, shows how easily the wireless switch can be installed in minutes to control lighting from multiple locations, even without the need for additional wiring or a gateway system.

What is Home/Away Wireless Smart Switch

The Legrand Home/Away wireless smart switch with Netatmo (WNAL33W1), is a battery-powered control device designed for smart lighting systems. It allows users to activate preset “Home” and “Away” lighting scenes with a single press. These scenes automatically adjust multiple lights at once for convenience and safety.

This 1-gang smart switch works wirelessly with primary smart switches and does not require physical wiring. It can be installed in a box or mounted anywhere on the wall, such as near the main entrance or garage door. When leaving home, it can turn off selected lights, and when arriving, it can switch them on instantly.

The device operates as part of a smart ecosystem using a gateway and mobile app. Users can create and manage lighting scenes, connect multiple smart devices, and control everything remotely. It improves flexibility, energy efficiency, and overall home automation experience.

Good to Know:

  • Smart wireless switches do not directly control a load. It requires primary smart devices used with load e.g. lighting points to control from different locations in 3-way or multi-way switching control.
  • This smart wireless device is powered by a replaceable long-life 3V lithium battery cell (CR2032).
  • The installation process of WNAL33W1 is same for other smart wireless home/away switches by Legrand such as WNAL33M1 or WNRL33WH, wake/sleep switches such as WNAL43W1, WNRL43NI, WNRL43WH, or WNRL43LA, and wireless smart switches such as WNRL23WH.
  • These wireless smart switches by Legrand is compatible with Amazon Alexa, Apple Home Kit, Google Home and other home automation systems.
  • The smart wireless switch can be used to create and manage 8 scenes per system using the Home+ Control app in commercial, multi-dwelling units, and residential applications.
  • A Smart Gateway is required for the Legrand wireless smart switch in conjunction with other wired smart devices i.e. smart switches and dimmers. For proper operation, it must also be paired with an adorne® or radiant® smart switch with Netatmo, or a smart plug-in switch with Netatmo.

Wiring a Home/Away Wireless Smart Switch

The Home/Away Wireless Smart Switch is a battery-powered scene controller. It does not require line/load wiring, unlike traditional switches. Instead, it communicates wirelessly with other Netatmo smart devices.

However, this switch requires grounding wire when mounted in an electrical box or replacing with an existing switch. The installation is fast, flexible, and ideal for multi-location lighting control without running new cables. This way, the connected load can be controlled through the mobile app or manual operation.

Although no physical wiring connections are required during installation, it is recommended to turn off power at the breaker or main service panel as a safety precaution (especially when mounting the device in an electrical box).

You can install the smart warless switch in two ways:

  • Inside a standard electrical wall box
  • Directly on a wall surface (no box required)

Installation in Electrical Box

Remove the label at the back of the device. This exposes the bult-in green grounding wire in the switch.

Locate the ground wire (from branch circuit) in the box (mostly, bare conductor, green or green with yellow stripe). Connect the device ground wire to the box ground using the provided wire connector. This is the only conductor required to install.

As the device is wireless, no line, neutral, or load connections are needed to connect. If installed alongside wired smart devices (e.g., WNAL10, sofTap switch or other wired Netatmo device ), terminate spare wires as per their instructions.

In case of replacing with an existing switch, handle other wires carefuly (if present) i.e. add wire connectors to the bare conductors and safely keep inside the box.

If you are going to install in Multi-Gang, replace single frame with multi-gang frame. Snap device into the frame and secure with mounting screws. Finally, fix the switch to the wall box using screws.

Click image or open in a new tab to enlarge

How to Install a Home - Away Wireless Smart Switch

Mounting on the Wall Surface

If not using a box, select a proper location where you need to mount the switch.

Apply double-sided adhesive strips at marked positions. Stick onto a smooth surface (tiles, finished wall).

Adhesive is not recommended for heavy or premium wall plates. In this case, use drywall screws or anchors for rough surfaces.

After installation, attach the wall plate by snapping it onto the frame and adjust fit using built-in click positions.

Power and Setup

Remove the battery insulation tab (CR2032 battery include). To pair with system, install the Legrand Home + Control app and follow app instructions to connect to home network or pair with gateway and smart devices.

For smart lighting control, follow this step-by-step guide for the Netatmo system to select your gateway, primary device, and add-on devices.

To enable Amazon Alexa, Google Home Voice Control Integration or or voice assistance to create scene for adorne & radiant® With Netatmo, follow this setup guide for automation.

To verify the operation, the LED indicator will blink green when connecting and turn solid when connected successfully.

If you need to reset to the factory default (when Required), press and hold the EZ button for 7 seconds. LED will blink red, then turns off. The device reset is complete.

Instructions & Precautions

  • Make sure to disconnect the power supply by switching OFF the breaker in the main panel before doing any electrical work.
  • The wire length from smart switch to other companion device should not exceed 300 ft (90 meters).
  • Smart devices are only suitable for indoor use, and should not be used for medical applications.

Disclaimer:

  • The author will not be liable for any losses, injuries, or damages from the display or use of this information or if you try any circuit in wrong format. So please! Be careful because it’s all about electricity and electricity is too dangerous.  If you are unsure, contact a licensed electrician to do it according to the local area codes.

Resources:

Smart Devices Wiring Series

Wiring Standard GFCI & Breakers

Wiring General Outlets & GFCI/AFCI Receptacles

Switches Wiring

Sizing Breakers, Wires & Panels

Finding the Number of Breakers/Outlets in a Circuit

Electrical Technology

We are a professional team specializing in Electrical and Electronic Engineering & Technology. Join us on the Electrical Technology Official WhatsApp Channel to receive the latest content, articles, and updates. You can also follow us on our social media platforms given below or subscribe via email to get premium engineering articles delivered directly to your inbox.

Leave a Reply

Your email address will not be published. Required fields are marked *

Back to top button