How to Wire 4-Way Switch (NEC) or Intermediate Switch as 3-Way (IEC)?
How to Wire an Intermediate Switch as Three-Way Switching & Wiring Crossover Switch as Four-Way Switching – IEC & NEC
Table of Contents
What is 4-Way Switch and 3-Way Switch – NEC & IEC?
There is no difference between 4-way switch (NEC) and 3-Way switch IEC e.g. it represents the same thing.
- North America – US: It is known as the 4-Way Switch or Crossover Switch. The pair of wires connecting the two switches (4-Way & 3-Way) are known as travelers.
- UK, EU & IEC following Countries: It is known as 3-Way Switch or Intermediate Switch. The pair of wires connecting the two switches (3-Way & 2-Way) are known as strappers.
In short, a 4-Way Switch (US) or 3-Way (Intermediate) Switch is a DPDT is a “Double Pole Double Throw” switch having four terminals.
4 – Way Switch – DPDT, Double Pole, Double Throw – US – NEC
3 – Way Switch – DPDT, Double Pole, Double Throw – UK – IEC
Difference Between 4-Way and Double Pole Switches (US – NEC).
- Both 4-Way switch and Double Pole switch look similar and have 4 terminals screws The device rating differentiate them. Alternatively, the switch terminals can be tested using a multimeter in the continuity test mode.
- 4-Way switches are rated for 120V – 277V, while double pole switches are rated for 220V to 240V.
- 4-Way switch divert both wires when switch position is changed, while double pole switch turns ON or OFF both wires.
- When switch position is changed, the 4-Way switch diverts (interchanges) both wires while double pole switch turns ON or OFF both wires.
Related Posts:
- How to Wire Single Pole, Single Throw (SPST) as 2-Way & 1-Way Switch? IEC & NEC
- How to Wire Single Pole, Double Throw (SPDT) as 3-Way & 2-Way Switch? IEC & NEC
What is DPDT Switch?
DPDT (stands for Double Pole Double Throw) switch is used to control two different circuits at the same time e.g. home appliances such as lighting circuits etc. Due to the common lever, it is used to control a single operation either ON or OFF between two electric circuits such as corridor or staircase wiring installation where a lighting point is controlled from more than two places.
DPDT switch has 6 terminals where 2 of them are used as common while the rest are used as travelers or signal pins.
Good to know: DPDT switch is known as double pole, double throw, crossover switch or 4-way switch in North America (US – NEC). While it is known as three Way switch or intermediate Switch in the Europe, UK and IEC following countries.
What is Intermediate Switch?
Intermediate switch is known as 3-Way switch in the UK and IEC following countries, while it is known as crossover or 4-way switch in North America and US.
The 4-way switch has four terminals (for travelers wires) plus ground terminals in the US. While in the UK, it has only four terminals namely L1, L2, L3 and L4.
The main four terminals are used to divert the flow of electric current from one position to another. For this reason, 4-Way switches (intermediate switches) are used to control a single circuit from more than two locations such as 2-way & Three way switching circuits, hallway & corridor wiring, hostel wiring, hospital wiring, tunnel wiring, godown wiring, staircase wiring etc.
Intermediate (or 4-Way Switch) can be used to control a lighting point from any number of locations. For example, if we need to control a light bulb from six places, we will need four numbers of 4-way switches and two numbers of 3-way switches.
The following fig and gif shows how is a 4-way switch working with 3-way switches to control an LED lamp from three different locations (alternately, 3-way switch wired with 2-way switches to control a lamp from 3 places – according to IEC).
Click image to enlarge
Click image to enlarge
Here is the short video format.
Let’s know how how to wire three-way and four-way switches one by one for different load points according to NEC and IEC.
Click image to enlarge
The above wiring diagrams are shown as a schematic diagram using symbols as below.
Related Posts:
Wiring 4-Way Switch (DPDT) for 120V/240V Circuits – NEC
How to Control a Light Bulb from Three Different Places using 4-Way and 3-Way Switches?
The following wiring diagram shows that a light bulb is wired and controlled from three different places using the DPDT and SPDT switches. As shown, there are three incoming wires from the breaker in the electrical box e.g. L (Line or Hot), N (Neutral) and G (Ground).
To control the light bulb from three different places, we need two, 3-Way switches and one 4-way switch.
The ground wire is connected to the Ground terminals of both (1st and last) 3-way switches as well as the 4-way switch (Green with yellow stripe). The incoming Line (as hot) is connected to the line terminal (common as black screw) of the first 3-way switch. The brass terminals of the 3-way switch are connected to the first pair of terminal screws of the 4-way switch via travelers wires. The second pair of terminal screws of the 4-way switch is connected to the travelers wires to the brass terminals of the second 3-way switch.
The common terminal of the second 3-way switch is connected to the light bulb holder. Keep in mind that neutral wire is never connected to the switches.
Finally, the neutral and ground wire is directly connected to the lamp holder. This way, the lamp can be controlled for ON/OFF operation from three places.
Click image to enlarge
Keep in mind that you can control the light point from any number of locations. For example, in the following wiring diagram, a light bulb is controlled from five different locations using three numbers of 4-way switches and two numbers of 3-way switches.
Click image to enlarge
Related Posts:
Wiring 3-Way (Intermediate) DPDT Switch for 230V Circuits – IEC
How to Control a Light Bulb from Three Different Locations using 3-Way (Intermediate) and 2-Way Switches?
In the following wiring diagram for 230V AC supply system – IEC, two 1-gang two way switches and an intermediate switch (3-way) is used to control a light bulb from three different locations. The fig shows that the incoming Phase (Line) wire (brown Color) is connected directly to the common terminal of the first 2-way switch. The L1 and L2 terminals of both 2-way switches are connected through strappers (Black & Gray) Wires to the L1, L2 & L3, L4 terminals of 3-way switch respectively. The common terminal of the second 2-way switch is connected to the bulb holder.
Finally, the Neutral (Blue) and Ground (Green with yellow stripe) is connected to the light bulb holder.
Click image to enlarge
This way, the light bulb can be controlled for ON and OFF operations from three different places using two-way switches and 3-way switches i.e. intermediate switches.
Keep in mind that you can control the light point from any number of locations. For example, in the following wiring diagram, a light bulb is controlled from six different locations using 4 numbers of intermediate switches and two numbers of 2-way switches.
Click image to enlarge
Related Posts:
- How to Control a Lamp by a Single Way or One-Way Switch?
- How to control each lamp by separately switch in parallel lighting circuit?
Precautions:
Related Posts:
- How to Wire an Outlet Receptacle? Socket Outlet Wiring Diagrams
- How to Find the Number of Outlets on a Single Circuit Breaker?
- How to Find Voltage & Ampere Rating of Switch, Plug, Outlet & Receptacle
- How to Wire a Pilot Light Switch? Wiring of 2 & 3 Way Neon Light Switches
- How to Wire Combo Switch and Outlet? – Switch/Outlet Combo Wiring Diagrams
- How to Wire an AFCI Combo Switch – AFCI Switch Wiring Diagrams
- How to Wire GFCI Combo Switch and Outlet – GFCI Switch/Outlet Wiring Diagrams
- How to Control Water Heater using Switches?
- How to Wire a Ceiling Fan? Dimmer Switch and Remote Control Wiring
- How to Wire Auto & Manual Changeover & Transfer Switch – (1 & 3 Phase)
- Automatic Bathroom Light Switch Circuit Diagram and Operation
- Staircase Wiring Circuit Diagram – How to Control a Lamp from 2 Places by 2-Way Switches?
- 2 Way Switch – How to Control One Lamp From Two or Three Places?
- How to Control One Light Bulb from Six Different Places using 2-Way & Intermediate Switches?
- Corridor Wiring Circuit Diagram – Hallway Wiring using 2-Way Switches
- Hospital Wiring Circuit for Light Control using Switches
- Tunnel Wiring Circuit Diagram for Light Control using Switches
- Godown Wiring Diagram -Tunnel Wiring Circuit and Working
- Hostel Wiring Circuit Diagram and Working
- How to Wire a UK 3-Pin Plug? Wiring a BS1363 Plug
- How to Wire a UK 3-Pin Socket Outlet? Wiring a BS1363 Socket
- How to Wire a Twin 3-Pin Socket Outlet? Wiring 2-Gang Socket
- How to Wire Combo Switch and Outlet? – Switch/Outlet Combo Wiring Diagrams
- Switch and Push Button Symbols
- Basic Electrical Wiring Diagrams
I remember doing this when I was an apprentice back in the 60’s the guy trying to teach us tried to insist that you could not have a lamp that could be turned on or off at 3 or more places he tried stating that there was no way to do it without using relays but I was intrestered as the building we were in had 3 exits which all had a light switch where no matter where the other switches were turned to you could still control the lights (except if someone held one of the switches half way) I spent several years repairing powered access machines which were controlled by basic switches which had 6 terminals and were center biased (so they sprung back to the center position when let go off) they had a pos on one side and neg on the other so if you pushed the switch one way you got line 1 with +12 volt and line 2 with -12 volt back at the centre you got nothing on either line and if you pushed the switch the opposite way you got -12 volt on line1 and +12 volt on line 2 which made operating the machines easy to set up when I first joined the company they stocked several different types of switches and never seamed to have the one they needed so had to return to the stores for most jobs they did I changed it so all they needed was to carry 3 different switches which they could adapt for any job they went from needing 8 different types of switches to only needing to carry two different types of switch plus a little knowledge on how to adapt them for every job.