How to Install a Wireless Smart Scene Switch
Wiring Installation of a Wireless Smart Scene Switch for Controlling Four Lighting Scenes
What is Wireless Smart Scene Switch?
A wireless smart scene switch is a modern lighting control device that allows you to activate multiple preset lighting “scenes” with a single touch. Instead of controlling one light at a time, it lets you group lights, dimmers, or outlets into customized settings (such as “movie night” or “evening mode”) and switch between them instantly. This improves both convenience and the overall lighting experience in a home.
The adorne® wireless smart scene switch (WNACB40) with Netatmo by Legrand is powered by 3V battery and operates without traditional wiring. It uses wireless communication to connect with a smart lighting system. The switch works with a dedicated smart gateway and uses a mesh network to ensure reliable performance across larger homes. It integrates with a mobile app, allowing users to easily create, modify, and manage lighting scenes from a smartphone or tablet.
The device is designed for flexible installation in just few minutes. It can be mounted on any wall without tools or electrical connections, making it ideal for retrofits or multi-location control. The device is compatible with Amazon Alexa, Google Assistant, Apple HomeKit, and other home automation systems. Therefore, the wireless smart scene switch is a perfect choice for smart lighting control in residential and commercial spaces.
The smart scene warless switch can be pair with other wired and wireless smart devices by adorne with Netatmo such as smart switches, dimmers and outlets.
- Related Post: How to Wire Smart Scene Controller Switch
Wiring a Wireless Smart Scene Switch
A wireless smart scene switch is a battery-powered controller used to operate multiple smart lighting scenes without physical wiring to the load. It communicates via RF with a gateway or smart devices.
In the following wiring tutorial, we will show how to wire a 1-gang wireless smart scene controller with four switches in a single unit for 120V AC lighting circuits.
Before installation, turn OFF power at the main breaker (even though device is wireless, this is required for safety when working near boxes or installing in an existing box instead of mounting on the wall.) When mounting the switch, maintain minimum 90 mm distance from the body for RF compliance.
Installation in Electrical Box
In installation of 1-gang box, remove the ground wire label from the back. Connect the ground wire to the box ground using wire nut.
Cap any unused wires inside the box. Finally, place the device frame over the box and secure using mounting screws
If installing in multi-gang box, remove device from its frame and replace with adorne multi-gang frame. Insert device into new frame and fix using frame mounting screws.
Click image or open in a new tab to enlarge
Wall Surface Installation
If mounting directly on the wall (no box involved), adhesive mounting is preferred for smooth surfaces such as tiles. To do so, use the provided double-sided adhesive strips.
In case of rough surfaces, heavy or metal wall plates, adhesive mounting is not recommended. Instead, use screw mounting. In this case, use drywall screws into stud or drywall anchors if studs are not used. stud are used.
In case of frame and wall plate installation, Remove spacers from the frame (not always required) and attach device to frame. Snap wall plate onto frame and adjust using 3 click-stop positions for proper alignment.
Powering, Paring and System Setup
The device uses pre-installed “CR2032” 3V lithium battery. For setup, remove the battery insulation tab to power the switch. To pair with system, install the Legrand Home + Control app and follow app instructions to connect to home network or pair with gateway, add scene controller and other smart devices. The scenes can be configured in Settings > Scenes.
For manual pairing (without network), Press gateway EZ button for 5 seconds. When LED becomes solid green,
press any button on the scene switch.
LED will blink green then turn OFF. Press gateway EZ button again briefly until all LEDs turn OFF. The paring is complete.
For smart lighting control, follow this step-by-step guide for the Netatmo system to select your gateway, primary device, and add-on devices.
To enable Amazon Alexa, Google Home Voice Control Integration or or voice assistance to create scene for adorne & radiant® With Netatmo, follow this setup guide for automation.
LED indicator indicates different states of the wireless smart scene switch i.e.
- Blinking Green: Device is trying to connect to network
- Off: Idle or setup complete
- Solid Green: (Gateway) Ready for pairing
To reset the switch to factory default, press and hold the EZ button for 10 seconds. Wait until the LED starts blinking red. Then release the EZ button; the LED will turn OFF, which indicates that the reset is complete.
Instructions & Precautions
- Make sure to disconnect the power supply by switching OFF the breaker in the main panel before doing any electrical work.
- The wire length from smart switch to other companion device should not exceed 300 ft (90 meters).
- Smart devices are only suitable for indoor use, and should not be used for medical applications.
Disclaimer:
- The author will not be liable for any losses, injuries, or damages from the display or use of this information or if you try any circuit in wrong format. So please! Be careful because it’s all about electricity and electricity is too dangerous. If you are unsure, contact a licensed electrician to do it according to the local area codes.
Resources:
Smart Devices Wiring Series
- How to Wire a Smart Switch in a 120/240V Load Center
- How to Wire 120/240V Smart Load Center with Smart Breakers
- How to Wire a Smart Breaker in a Smart 120/240V Panel
- How to Wire a Smart GFCI Breaker in a 120/240V Smart Panel
- How to Wire Smart AFCI/GFCI Breaker in a Smart Load Center
- How to Wire a 15A Wi-Fi Smart Outlet in a Smart Panel
- How to Wire 15A and 20A Wi-Fi Smart GFCI Outlets
- How to Wire Z-Wave Smart Switch, Dimmer & Fan Speed Controller
- How to Wire a Digital and Wi-Fi Smart LED Dimmer Switch
- How to Wire a Smart Switch Companion with a Smart Switch
- Wiring a Smart Dimmer Switch Companion with a Digital Dimmer
- How to Install a Wire-Free Smart Dimmer Anywhere Companion
- How to Wire Smart Scene Controller Switch
Wiring Standard GFCI & Breakers
- How to Wire a 1-Pole Breaker
- How to Wire a 2-Pole Breaker
- How to Wire a 3-Pole Breaker
- How to Wire a 1-Pole GFCI
- How to Wire a 2-Pole GFCI
- How to Wire a 3-Phase, 3-Pole GFCI
- How to Wire a Tandem Breaker
- How to Wire GFCI Circuit Breakers
- How to Wire an AFCI Breaker
Wiring General Outlets & GFCI/AFCI Receptacles
- How to Wire an Outlet Receptacle? Socket Outlet Wiring Diagrams
- How to wire a GFCI Outlet?
- How to Wire an AFCI Outlet?
- How to a Wire 3-Way Combination Switch and Grounded Outlet?
- How to Wire a 15A – 125V Outlet – NEMA 5-15 Receptacle
- How to Wire a 20A – 125V Outlet – NEMA 5-20 Receptacle
- How to Wire a 15A – 250V Outlet – NEMA 6-15 Receptacle
- How to Wire a 20A – 250V Outlet – NEMA 6-20 Receptacle
- How to Wire a 50A – 125/250V Outlet – NEMA 14-50 Receptacle
Switches Wiring
- How to Wire Single Pole, Single Throw (SPST) as 2-Way Switch?
- How to Wire Single Pole, Double Throw (SPDT) as 3-Way Switch?
- How to Wire Double Pole, Single Throw Switch? Wiring DPST
- How to Wire Double Pole, Double Throw Switch? Wiring DPDT
- How to Wire Double Switch? 2-Gang, 1-Way Switch – IEC & NEC
- How to Wire 4-Way Switch (NEC) or Intermediate Switch as 3-Way (IEC)?
- How to Wire Auto & Manual Changeover & Transfer Switch – (1 & 3 Phase)
Sizing Breakers, Wires & Panels
- How to Size a Load Center, Panelboards and Distribution Board?
- How to Determine the Right Size Capacity of a Subpanel?
- How to Find the Right Wire Size for 100A Service 120V/240V Panel?
- How to Size a Circuit Breaker?
- How to Find the Proper Size of Wire & Cable In Metric & Imperial Systems
- How to Size a Breaker and Wires in AWG with EGC for Load?
- How to Size Service-Entrance Conductors and Feeder Cables?
- How to Size Feeder Conductors with Overcurrent Protection
- How to Size a Branch Circuit Conductors with Protection?
- How to Size Equipment Grounding Conductor (EGC)?
- How to Size Grounding Electrode Conductor (GEC)?
- How to Size Main Bonding Jumper (MBJ)?
- How to Size Motors FLC, HP, Voltage, Breaker Size and Wire Size
- What is the Correct Wire Size for 100A Breaker and Load?
- What is the Right Wire Size for 15A Breaker and Outlet?
- What is the Suitable Wire Size for 20A Breaker and Outlet?
Finding the Number of Breakers/Outlets in a Circuit
- How to Determine the Number of Circuit Breakers in a Panelboard?
- How to Find the Number of Outlets on a Single Circuit Breaker?
- How to Find Voltage & Ampere Rating of Switch, Plug, Outlet & Receptacle
- How to Calculate the Number of Fluorescent Lamps in a Final Sub Circuit?
- How to Calculate the Number of Incandescent Lamps in a Final Sub Circuit?
- How to Determine the Number of Lighting Branch Circuits?
- How to Determine the Number of Branch Circuits? – 3 Ways
- How to Find the Number of Lights on a Single Circuit Breaker?